config:remotecontrol:airlab [2016/09/01 07:13] – created twconfig:remotecontrol:airlab [2019/07/09 16:18] (current) – external edit 127.0.0.1
Line 1: Line 1:
-====== D&R AIRLAB Mk. 2 Remote Support ======+====== D&R AIRLAB Remote Control ======
  
 +The [[http://www.d-r.nl/airlab.html|D&R AIRLAB]] is a modular analog mixing console. It has a serial port which can be used for fader start with mAirList. There is also a USB control module with push buttons for the cartwall etc. available.
 +
 +===== Supported Hardware =====
 +
 +  * AIRLAB Mk 2
 +  * AIRLAB DT
 +
 +===== Fader Start Configuration =====
 +
 +The AIRLAB has a serial port used for fader starts. You need a physical serial port, or a USB/serial adapter, on your computer.
 +
 +(Depending on your hardware configuration, there might also be a USB port used for the push button control module - see instructions below).
 +
 +The first step is to set the serial communication parameters correctly. Open the mAirList standalone config app, go to //Misc. -> Serial Ports//, and set the parameters of the corresponding port as follows:
 +
 +  * Baud rate: 57600
 +  * Byte size: 8
 +  * Parity: N
 +  * Stop bits: 1
 +  * Receive buffer: 4096
 +  * Send buffer: 4096
 +
 +Next, go to the //Remote Control// page, and add a new //D&R Airlab// remote.
 +
 +==== Communication ====
 +
 +On the //Communication// tab, select the COM port that your console is attached to. 
 +
 +{{ :config:remotecontrol:pasted:20160901-113542.png?400 }}
 +
 +Don't forget to set the communication parameters on the //Serial Ports// page correctly, see above.
 +
 +==== Channels ====
 +
 +On the //Channels// tab, you can define fader start commands for any of the 16 channels of the AIRLAB:
 +
 +{{ :config:remotecontrol:pasted:20160901-113617.png?400 }}
 +
 +Just select or type any [[reference:remote_control_commands|remote control command]] for "On" (fader goes on) or "Off" (fader goes off).
 +
 +==== On Air ====
 +
 +The AIRLAB has two On Air busses which can be switched separately. On the //On Air// tab, you can assign remote control commands to these switching events:
 +
 +{{ :config:remotecontrol:pasted:20160901-113817.png?400 }}
 +===== USB Control Module =====
 +
 +D&R offers an optional USB Control Module with 16 cartwall push buttons and 8 additional customizable keys.
 +
 +This module is compatible with the similar control module of the D&R AIRENCE control. To use it with mAirList, just follow the instructions for the setup of the [[config:remotecontrol:airence|D&R AIRENCE remote control]] (only the Cartwall and Switches tabs, not the players).
 +
 +So if you are using an AIRLAB with the USB Control Module, you will need to add two remote controls to your mAirList configuration: AIRLAB (for fader starts) and AIRENCE (for the control module).